<tt><font size=2>> nsca[10902]: Dropping packet with invalid CRC32
- possibly due to <br>
> client using wrong password or crypto algorithm?</font></tt>
<br><tt><font size=2>>  </font></tt>
<br><tt><font size=2>> Obviously, I’ve triple-checked the password
and algorithm settings, <br>
> so that’s not the problem.</font></tt>
<br><tt><font size=2>> </font></tt>
<br><tt><font size=2>> I’m suspecting that since the collector is running
a 64 bit version <br>
> of SLES (10.2) and the central server is 32 bit SLES (10.2), that
<br>
> somehow the CRC is being generated differently between the two.</font></tt>
<br><tt><font size=2>>  </font></tt>
<br><tt><font size=2>> Another bit of evidence pointing to the suspected
mismatch is that <br>
> the collector in question can do send_nsca successfully to another
<br>
> 64 bit system.</font></tt>
<br><tt><font size=2>>  </font></tt>
<br><tt><font size=2>> Anyone else run into this or can think of a workaround
to try?</font></tt>
<br>
<br><tt><font size=2>I am pretty sure there's no general problem with a
64 bit send_nsca</font></tt>
<br><tt><font size=2>and a 32 bit nsca-daemon, as I am using this setup
massively.</font></tt>
<br><tt><font size=2>Most of our Oracle servers are RHEL5 64bit and our
Nagios is a</font></tt>
<br><tt><font size=2>RHEL5 32bit. So it must be either a misconfiguration
on your side,</font></tt>
<br><tt><font size=2>or a SLES specific problem. Even though you triple
checked it, check</font></tt>
<br><tt><font size=2>it again - and I'd suppose to just start the integration
of that</font></tt>
<br><tt><font size=2>particular server from scratch again. Maybe you made
such an obvious</font></tt>
<br><tt><font size=2>mistake that even looking 10 times over it would not
reveal it to</font></tt>
<br><tt><font size=2>you. Human beings tend to overlook obvious mistakes
they made</font></tt>
<br><tt><font size=2>themselves - our brain is tricking us there ;)</font></tt>
<br>
<br><tt><font size=2>I'd say the top mistake of all the "I checked
it ten times and the</font></tt>
<br><tt><font size=2>config is correct!"-problems I heard of is: your
send_nsca is using</font></tt>
<br><tt><font size=2>another config then you think it does. Therefor you
always check the</font></tt>
<br><tt><font size=2>wrong config and the real config has a mistake. Just
a hint.</font></tt>
<br>
<br><tt><font size=2>Else I can't think of much else, as this setup is
running here</font></tt>
<br><tt><font size=2>without problems. Last question though: are you using
a 32bit</font></tt>
<br><tt><font size=2>precompiled send_nsca on the 64bit system or did you
compile</font></tt>
<br><tt><font size=2>it natively on that system for 64bit?</font></tt>
<br>
<br><tt><font size=2>S</font></tt>
<br>
<br>
<br>
<span style="font-family:sans-serif,helvetica; font-size:10pt; color:#000000">GFKL Financial Services AG</span><br>
<span style="font-family:sans-serif,helvetica; font-size:10pt; color:#000000">Vorstand: Jürgen Baltes, Dr. Tom Haverkamp</span><br>
<span style="font-family:sans-serif,helvetica; font-size:10pt; color:#000000">Vorsitzender des Aufsichtsrats: Wilhelm Plumpe</span><br>
<span style="font-family:sans-serif,helvetica; font-size:10pt; color:#000000">Sitz: Limbecker Platz 1, 45127 Essen, Amtsgericht Essen, HRB 13522</span>